MIL-DTL-60318C (AR)
TABLE III. FIRST ARTICLE INSPECTION
CLASSIFICATION OF CHARACTERISTICS
PARAGRAPH
TITLE
DRAWING NUMBER
N/A
M1 Propellant
SHEET 1 OF 1
NEXT HIGHER ASSEMBLY
9205471/9288696
CATEGORY
EXAMINATION OR TEST
CONFORMANCE
REQUIREMENT
PARAGRAPH REFERENCE/
CRITERIA
PARAGRAPH
INSPECTION METHOD
Critical
Zone 7 pressure
4.4.3.2
3.3
4.5
(Maximum mean pressure or maximum
individual pressure)
Major
101
Zone 3 pressure
4.4.3.2
3.3
4.5
102
Individual pressure
4.4.3.2
3.4
4.5
103
Velocity standard deviation
4.4.3.2
3.4
4.5
Dwgs.
3.2
104
Propellant charge
4.5/Balance weight
9205471/9288696
Dwgs.
3.2
105*
Bag material
AIE (see note)
9205471/9288696
Dwgs.
3.2
106*
Bag size
Visual
9205471/9288696
Dwgs.
3.2
107*
Thread material
AIE (see note)
9205471/9288696
Dwgs.
3.2
108*
Bag marking
Visual
9205471/9288696
109
Composition outside of limits specified
4.4.3.1
3.2
IAW MIL-STD-652
110
Total volatile too high
4.4.3.1
3.2
IAW MIL-STD-652
111
Moisture above/below limits
4.4.3.1
3.2
IAW MIL-STD-652
112
Compressibility too low
4.4.3.1
3.2
IAW MIL-STD-652
113
Form and dimensions
4.4.3.1
3.2
IAW MIL-STD-652
114
Heat test
4.4.3.1
3.2
IAW MIL-STD-652
115
Initial production testing
Table IX
3.1
4.5
Minor
Dwgs.
3.2 and 3.5
Visual
201
Evidence of poor workmanship
9205471/9288696
* Failures in compliance to Major 105 to 108 will lead to rejection of test samples only, not propellant lot.
Note: Approval of inspection equipment design (AIE), see 6.10.1.
7
For Parts Inquires submit RFQ to Parts Hangar, Inc.
© Copyright 2015 Integrated Publishing, Inc.