MIL-DTL-248D
4.3.2.6 Classification of characteristics - Sealed Fiberboard Box (see dwgs. 7548645).
Classi
Examination/test
Conformance
Requirement
Inspection
fication
criteria
paragraph
method ref..
Critical: None defined
Major:
101. Assembly torn or pierced
Level IV
3.5 & 5.1
Visual
102. Liner pierced or torn
Level IV
3.5 & 5.1
Visual
103. Liner improperly closed
Level IV
3.5 & 5.1
Visual
104. Lot number misleading or
Level IV
3.5 & 5.1
Visual
unidentifiable
105. Strapping or banding strips
Level IV
3.5 & 5.1
Visual/manual
missing, broken, or loose.
Minor:
201. Type of liner incorrect
Level II
3.5 & 5.1
Visual
202. Marking misleading or
Level II
3.5 & 5.1
Visual
unidentifiable
203. Strapping or banding strips
improperly assembled
Level II
3.5 & 5.1
Visual
204. Flaps improperly closed
Level II
3.5 & 5.1
Visual
(as applicable).
4.3.2.7 Classification of characteristics - TNT. (See 6.7 & 6.8)
Classi
Examination/test
Conformance
Requirement
Inspection
fication
criteria
paragraph
method ref..
Critical: None defined
Major:
101.
Form
4.3.3.1/4.3.3.2
3.2
4.4.1.1
102.
Color
3.2
4.4.1.2
103.
Solidification Point
4.3.3.1/4.3.3.2
3.2
4.4.2
104.
Moisture
4.3.3.1/4.3.3.2
3.2
4.4.3
105.
Acidity
4.3.3.1/4.3.3.2
3.2
4.4.4
106.
Alkalinity
4.3.3.1/4.3.3.2
3.2
4.4.5
107.
Insoluble matter
4.3.3.1/4.3.3.2
3.2
4.4.6
108.
Sodium
4.3.3.1/4.3.3.2
3.2
4.4.7
109.
Thickness of flake
4.3.3.1/4.3.3.2
3.3
4.4.8
110.
Granulation
4.3.3.1/4.3.3.2
3.4
4.4.9
111.
Flake size
100%
3.4.1
4.4.11.1
11
For Parts Inquires submit RFQ to Parts Hangar, Inc.